WASTEWATER QUALITY MONITORING. CASE STUDY: CLUJ-NAPOCA

Authors

  • Călin Daniel VÂTCA Babeş-Bolyai University, Faculty of Environmental Science and Engineering, 400294 Cluj-Napoca, Fântânele No. 30, Romania.
  • Ildiko Melinda MARTONOȘ Babeş-Bolyai University, Faculty of Environmental Science and Engineering, 400294 Cluj-Napoca, Fântânele No. 30, Romania. *Corresponding author: ildi62004@yahoo.com https://orcid.org/0000-0003-4590-943X
  • Radu MIHĂIESCU Babeş-Bolyai University, Faculty of Environmental Science and Engineering, 400294 Cluj-Napoca, Fântânele No. 30, Romania.

DOI:

https://doi.org/10.24193/subbambientum.2017.2.08

Keywords:

wastewater, treatment plant, chemical parameters, Cluj-Napoca.

Abstract

In Romania, the critical situation of the wastewater treatment plants is caused by the old sewage networks and the purification installations, the modification of the sewage capacity without its adaptation to the constructive parameters, the poor managerial capacity and the poor financial situation of the public utility operators. The wastewater treatment plant from Cluj-Napoca, was recently upgraded, the technology was innovated and introduced the tertiary wastewater treatment stage. This unit collects and treats the wastewater from the city of Cluj-Napoca and from the adjacent areas. To evaluate the quality of the wastewater and of the treated water, the samples were collected over a period of 8 months (September 2015 - April 2016), daily, at the entrance and exit point from the treatment plant. Because our focus was mainly on the tertiary stage, the analyzed parameters were: pH, COD(Cr), BOD5, total suspensions, ammonium, nitrates, total N, total P. With regard to the quality of the analyzed waters, it can be concluded that all of the eight analyzed parameters show high values in the wastewater and after purification the values decrease, within the maximum permissible limits given by law. In the months with higher temperatures the quality of the wastewater is weaker, and we noticed that the monitored parameters are slightly higher but also the amount of wastewater increases. On the basis of the results we can say that the efficiency of the purification processes is very good and the tertiary stage introduced in the wastewater treatment process is of high importance especially in the reduction of the phosphorus content.

References

Dima M., 2005, Epurarea apelor uzate (in Romanian), Tehnopress Publishing House, Iași, 526 p.

Gligor E., Blaga A.C., 2009, Techniques for removing Nitrogen and Phosphorus through chemical addition. Analele Universităţii din Oradea, Fascicula de Energetică, XV, pp. 232-239.

Gligor E., Ionescu G.C., Dan F., Ionescu G.L., Sâmbeteanu A., 2010, Optimization and profitability of fermentation gas production facilities in wastewater treatment plants, using unconvetional sources. Analele Universităţii din Oradea, Fascicula Construcţii şi instalaţii hidroedilitare, XIII, pp. 305-311.

Ianculescu O., Ionescu Gh. C., Racoviţeanu R., 2002, Epurarea apelor uzate (in Romanian), Matrix Rom Publishing House, Bucharest.

Ionescu G.L., Ionescu G.C., Sâmbeteanu A., 2013, Tehnologii moderne pentru epurarea apelor uzate (in Romanian), Matrix Rom Publishing House, Bucharest, 315 p.

Nourmohammadi D., Esmaeeli M.B., Akbarian H., Ghasemian M., 2013, Nitrogen removal in a full-scale domestic wastewater treatment plant with activated sludge and trickling filter. J. Environ. Public Health, 2013, 6 p., doi: 10.1155/2013/504705.

Robescu L. D., Stroe F., Presură A., Robescu D. N., 2011, Tehnici de epurarea apelor uzate (in Romanian). Technical Publishing House, Bucharest, 279 p.

Wurhmann K., 1964, Hauptwirkung und Wechselwirk Kenndaten einiger Betriebsparameterim Belebschlamm system. Ergebnise mehrjahriger Grossversuche, Vortrag, Zurich.

NTPA – 001/2005 – Normative regarding the pollutants loading limits of the industrial and urban wastewater at evacuation to natural receptors (HG nr. 352/2005).

SR ISO 6060: 1996, Water quality.Determination of chemical oxygen demand.

SR ISO 7890 - 1: 1998, Water quality. Determination of the nitrate content.

SR ISO 7150 - 1: 2001, Water quality. Determination of ammonium content. Part 1 SR EN 1899 - 1: 2003, Water quality. Determination of biochemical oxygen demand after n days (BODn).

SR EN 872: 2005, Water quality. Determination of the content of suspended matter. Filtration method on glass cutter filters.

SR EN ISO 6878: 2005, Water quality. Determination of phosphorus. Spectrophotometric method with ammonium molybdate.

SR ISO 10523: 2012, Water quality. Determination of pH.

Downloads

Published

2017-12-30

How to Cite

VÂTCA, C. D., MARTONOȘ, I. M., & MIHĂIESCU, R. (2017). WASTEWATER QUALITY MONITORING. CASE STUDY: CLUJ-NAPOCA. Studia Universitatis Babeș-Bolyai Ambientum, 62(2), 81–89. https://doi.org/10.24193/subbambientum.2017.2.08

Issue

Section

Articles